Buffer Gas Cooling in Penning Ion Traps

Abstract

In this study, Penning ion trap, which traps ions using electric field and magnetic field, is investigated. Penning traps are used in many laboratories around the world. Penning trap is used for mass determination as a mass spectrometer in basic physics research, for controlling quantum states and for ion trapping. Simbuca simulation program was used for other quantities of single ion or multiple ions such as ion dynamics and ion temperature. Simbuca is a modular Penning (ion) trap simulation program written in C++ programming language. Ideal Trap was used for ions. It is also used as a simulation of ion movement in a Penning trap with realistic Buffer gas collisions and Coulomb interaction using the A Graphics Card. However, Coulomb is a program applicable to other applications requiring charged particle tracking under the influence of electric and magnetic fields, with or without interaction.
Buffer Gas method was used to cool the trapped ions. Helium gas, one of the noble gas atoms, was used as buffer gas. Ion dynamics of ions before and after the use of buffer gas were investigated. The data from the trap is set to 1 ms. In addition, using the same trap parameters and initial values for ions, the temperature values before and after the application of buffer gas for 100 units of 7Li and 11B ions were calculated separately. In addition, temperature changes for different ions were investigated using Coulomb effect for 100 ions.

Keywords

Kaynakça

  1. [1] Wikipedia contributors. (2017, October 10). Ion trap. In Wikipedia, The Free Encyclopedia [online]. Available: https://en.wikipedi0.org/wiki/Ion_trap
  2. [2] P.M. Rao, R. D’Souza and S.A. Ahmad, Quadrupole ion traps, Resonance 6:4 (2001) 22-37.
  3. [3] L. S. Brown, G. Gabrielse, Geonium theory: Physics of a single electron or ion in a Penning trap, Reviews of Modern Physics, 58:1 (1986) 233.
  4. [4] J.R.C. Pita, Design, Development and operation of novel ion trap geometries, Ph.D. Thesis, Imperial College London (2007).
  5. [5] Wikipedia contributors. (2019, March 5). Penning trap. In Wikipedia, The Free Encyclopedia[online]. Available: https://en.wikipedi0.org/wiki/Penning_trap
  6. [6] K. Blaum, Y. Novikov, and G. Werth, Penning traps as a versatile tool for precise experiments in fundamental physics, Contemporary Physics,51(2) (2010) 149-175.
  7. [7] K. Blaum, High-accuracy mass spectrometry with stored ions, Phys. Rep. 425 (2006) 1-78.
  8. [8] G. Bollen. Lect. Notes Phys (Book style).2004, pp. 169-651.

Ayrıntılar

Birincil Dil

Türkçe

Konular

-

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

30 Haziran 2020

Gönderilme Tarihi

4 Aralık 2019

Kabul Tarihi

11 Mayıs 2020

Yayımlandığı Sayı

Yıl 1970 Cilt: 4 Sayı: 1

Kaynak Göster

APA
Dursun, H. İ., Durmuş, S., & Aksakal, H. (2020). Penning İyon Tuzaklarında Tampon Gaz Soğutma. Aksaray University Journal of Science and Engineering, 4(1), 43-65. https://doi.org/10.29002/asujse.655068
Aksaray J. Sci. Eng. | e-ISSN: 2587-1277 | Period: Biannually | Founded: 2017 | Publisher: Aksaray University | https://asujse.aksaray.edu.tr