EN
Recoil Analysis for Heavy Ion Beams
Abstract
Given that there are 94 clinics and more than 200,000 patients treated worldwide, proton and carbon are the most used heavily charged particles in heavy-ion (HI) therapy. However, there is a recent increasing trend in using new ion beams. Each HI has a different effect on the target. As each HI moves through the tissue, they lose enormous energy in collisions, so their range is not long. Ionization accounts for the majority of this loss in energy. During this interaction of the heavily charged particles with the target, the particles do not only ionize but also lose energy with the recoil. Recoil occurs by atom-to-atom collisions. With these collisions, crystalline atoms react with different combinations and form cascades in accordance with their energies. Thus, secondary particles create ionization and recoil. In this study, recoil values of Boron(B), Carbon(C), Nitrogen(N), and Oxygen(O) beams in the water phantom were computed in the energy range of 2.0-2.5 GeV using Monte Carlo simulation and the results were compared with carbon. Our findings have shown that C beams have 35.3% more recoil range than B beams, while it has 14.5% and 118.7% less recoil range than N and O beams, respectively. The recoil peak amplitude of C beams is 68.1% more than B beams, while it is 13.1% less than N and 22.9% less than O beams. It was observed that there is a regular increase in the recoil peak amplitude for C and B ions, unlike O and N where such a regularity could not be seen. Moreover, the gaps in the crystal structure increased as the energy increases.
Keywords
References
- [1] O. Jakel, C.P. Karger, J. Derbus. The future of heavy ion radiotherapy. Medical Phsics, 35 (2008) 5653-5663.
- [2] M. Durante, J.S. Loeffler. Charged particles in radiation oncology. Nature Reviews Clinical Oncology, 7 (2010) 37-43.
- [3] W.D. Newhauser, R. Zhang. The physics of proton therapy. Phys. Med. Biol., 60 (2015) R155-209.
- [4] PTCOG. Particle therapy co-operative group. https://www.ptcog.ch, Accessed date: 20.09.2019.
- [5] T. Tessonnier, T.T. Böhlen, F. Ceruti, A. Sala P. Ferrari, S. Brons, T. Haberer, J. Debus, K. Parodi, A. Mairani. Dosimetric verification in water of a Monte Carlo treatment planning tool for proton, helium, carbon and oxygen ion beams at the Heidelberg Ion Beam Therapy Center. Physics in Medicine adn Biology, 62 (2017) 6579-6594.
- [6] T. Tessonnier, A. Mairani, S. Brons, T. Haberer, J. Debus, K. Parodi. Experimental dosimetric comparison of 1H, 4He, 12C and 16C scanned ion beams. Physics in Medicine and Biology, 62 (2017) 3958-3982.
- [7] H. Fuchs, M. Alber, T. Schreiner, D. Georg. Implementation of spot scanning dose optimization and dose calculation for helium ions in Hyperion. Medical Physics, 42 (2015) 5157-5166.
- [8] A. Mairani, G. Dokic, T. Tessonnier, F. Kamp, D.J. Carlson, M. Ciocca, F. Cerutti, P.R. Sala, A. Ferrari, T.T. Böhlen, O. Jakel, K. Parodi, J. Debus, A. Abdollahi, T. Haberer. Biologically optimized helium ion plans: Calculation approach and its in vitro validation. Physics in Medicine and Biology, 61(2016) 4283-4299.
Details
Primary Language
English
Subjects
-
Journal Section
Research Article
Publication Date
December 30, 2022
Submission Date
March 21, 2022
Acceptance Date
August 17, 2022
Published in Issue
Year 1970 Volume: 6 Number: 2
APA
Ekinci, F., Bostancı, G. E., Güzel, M. S., & Dağlı, Ö. (2022). Recoil Analysis for Heavy Ion Beams. Aksaray University Journal of Science and Engineering, 6(2), 123-134. https://doi.org/10.29002/asujse.1090950
Cited By
Investigation of tissue equivalence of phantom biomaterials in 4He heavy ion therapy
Radiation Effects and Defects in Solids
https://doi.org/10.1080/10420150.2022.2153251MC TRIM Algorithm in Mandibula Phantom in Helium Therapy
Healthcare
https://doi.org/10.3390/healthcare11182523Enhancing Tissue Equivalence in 7Li Heavy Ion Therapy with MC Algorithm Optimized Polymer-Based Bioinks
Journal of Functional Biomaterials
https://doi.org/10.3390/jfb14120559Monte Carlo simulation of polymer phantoms in proton therapy for eye tumor treatment
The European Physical Journal Plus
https://doi.org/10.1140/epjp/s13360-024-05944-z